Skip to content
Particle Sizing Systems · AccuSizer · Nicomp

Entegris PSS particle analysis and sourcing support

PSS refers here to Particle Sizing Systems. Entegris announced its acquisition of Particle Sizing Systems, LLC in 2018 and currently provides the AccuSizer and Nicomp product families. Zhongfu helps customers organize product documents, configuration questions and purchase inquiries.

Updated: November 2, 2026 · Zhongfu Optoelectronic Technology (Wuhan) Co., Ltd.

Choose a measurement task before choosing a configuration

AccuSizer SPOS

Single-particle optical sizing combines a sensor, counting/pulse-height analysis and fluidics. Review this route for particle counts, concentration or a large-particle tail. Sample delivery and dilution are part of the measurement method.

Entegris AccuSizer SPOS product family
Official Entegris family image, used with permission. Appearance does not establish the supplied configuration.

Nicomp DLS / Zeta

Dynamic light scattering supports nano- and submicron-particle size analysis. The current product page distinguishes N3000 particle sizing from Z3000 size and Zeta-potential analysis. Do not assume all Nicomp configurations include both outputs.

Entegris Nicomp N3000 DLS particle size analyzer
Official Entegris Nicomp N3000 image, used with permission. Zeta-potential capability requires a separate configuration check.

Laboratory and online systems have different requirements

PSS configuration directions
TaskProduct directionCheck before requesting a quote
CMP slurry large-particle countingAccuSizer Mini / Mini FLEXSample point, sensor, dilution, mixing, flushing and data requirements. Mini FLEX is a specific product; do not transfer specifications from another Mini configuration.
Automated batch analysisAccuSizer A7000 DIStirring, sample volume, dilution mode and wash verification. An individual sample-cycle description does not define total batch throughput.
Syringe-injection liquid particle analysisAccuSizer A7000 SISSample method, sensor and included options. Software, automation and IQ/OQ documents must be confirmed in the quotation.
Nano-particle size or surface-charge studiesNicomp N3000 / Z3000Required measurement output, sample medium, concentration, accessories and method. Online Nicomp systems require a separate process-integration review.

These are product-family directions, not a universal operating range or compatibility statement. Bind specifications to the complete model and current manufacturer document, then evaluate the actual sample.

Preparing an actionable RFQ

Explain the result you need: particles/mL, a defined large-particle threshold, size distribution or Zeta potential. Provide the complete model or a label photo, sample medium and SDS, concentration, viscosity, temperature and known settling or bubble behavior.

Include online versus laboratory operation, sample quantity, dilution medium, mixing and wash requirements, utilities, interfaces and software/data needs. List calibration or qualification documents separately from any on-site work. These are procurement recommendations; they do not imply manufacturer approval for a particular sample.

Zhongfu Optoelectronic Technology (Wuhan) Co., Ltd. / 众甫光电科技(武汉)有限公司 supports document and RFQ coordination. Supply conditions, installation, training, service responsibility and delivery are confirmed in writing for each project. Distributor status requires separate evidence of the entity, territory, product scope and validity.

中文 PSS 产品总页 · Chinese PSS sourcing checklist

Manufacturer references

Reviewed . Product names and trademarks belong to their respective owners.

  1. Entegris acquisition announcement — January 22, 2018; PSS identity and product families.
  2. AccuSizer SPOS Systems — system features and applications.
  3. Nicomp Nano DLS/ZLS Systems — N3000 and Z3000 configuration directions.
  4. Mini FLEX data sheet, 7127-12974ENT-0623 — pp.1–2, fluidics and applications; p.4, specifications.
  5. A7000 DI data sheet, 7127-10462ENT-0626 — p.1, sampling method; p.2, specifications.
  6. A7000 SIS data sheet, 7127-10463ENT-0326 — pp.1–2, applications and optional items.

Questions before buying

Does a PSS distributor search prove sales authorization?

No. Verify the legal entity, territory, covered product families, validity period and written authorization. Content-use permission does not establish distribution or sales authorization.

Can SPOS and DLS results be used interchangeably?

They answer different measurement questions. AccuSizer SPOS measures individual particles and particle concentration; Nicomp DLS addresses nanoparticle size, with Zeta-potential capability depending on configuration. Define the required output before selecting a system.

What information should I send for a PSS RFQ?

Send the complete model or label photo, sample chemistry and SDS, concentration, measurement objective, online or laboratory use, sampling and dilution conditions, installation requirements, software needs, quantity and delivery region.

Contact Zhongfu for a PSS inquiry

Send the complete model, sample chemistry/SDS, measurement objective, fluidics, software and document requirements. We can start with a label or current-equipment photo.

Specifications, sample suitability, available options and supply/service scope require current manufacturer documents and written project confirmation.